// ahbinterface.sv
//
// Written: Ross Thompson ross1728@gmail.com
// Created: August 29, 2022
// Modified: 18 January 2023
//
// Purpose: Translates LSU simple memory requests into AHB transactions (NON_SEQ).
//
// Documentation: RISC-V System on Chip Design Chapter 6 (Figure 6.21)
//
// A component of the CORE-V-WALLY configurable RISC-V project.
//
// Copyright (C) 2021-23 Harvey Mudd College & Oklahoma State University
//
// SPDX-License-Identifier: Apache-2.0 WITH SHL-2.1
//
// Licensed under the Solderpad Hardware License v 2.1 (the “License”); you may not use this file
// except in compliance with the License, or, at your option, the Apache License version 2.0. You
// may obtain a copy of the License at
//
// https://solderpad.org/licenses/SHL-2.1/
//
// Unless required by applicable law or agreed to in writing, any work distributed under the
// License is distributed on an “AS IS” BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND,
// either express or implied. See the License for the specific language governing permissions
// and limitations under the License.
////////////////////////////////////////////////////////////////////////////////////////////////
`include "wally-config.vh"
module ahbinterface #(
parameter LSU = 0 // 1: LSU bus width is `XLEN, 0: IFU bus width is 32 bits
)(
input logic HCLK, HRESETn,
// bus interface
input logic HREADY, // AHB peripheral ready
output logic [1:0] HTRANS, // AHB transaction type, 00: IDLE, 10 NON_SEQ, 11 SEQ
output logic HWRITE, // AHB 0: Read operation 1: Write operation
input logic [`XLEN-1:0] HRDATA, // AHB read data
output logic [`XLEN-1:0] HWDATA, // AHB write data
output logic [`XLEN/8-1:0] HWSTRB, // AHB byte mask
// lsu/ifu interface
input logic Stall, // Core pipeline is stalled
input logic Flush, // Pipeline stage flush. Prevents bus transaction from starting
input logic [1:0] BusRW, // Memory operation read/write control: 10: read, 01: write
input logic [`XLEN/8-1:0] ByteMask, // Bytes enables within a word
input logic [`XLEN-1:0] WriteData, // IEU write data for a store
output logic BusStall, // Bus is busy with an in flight memory operation
output logic BusCommitted, // Bus is busy with an in flight memory operation and it is not safe to take an interrupt
output logic [(LSU ? `XLEN : 32)-1:0] FetchBuffer // Register to hold HRDATA after arriving from the bus
);
logic CaptureEn;
localparam LEN = (LSU ? `XLEN : 32); // 32 bits for IFU, XLEN for LSU
flopen #(LEN) fb(.clk(HCLK), .en(CaptureEn), .d(HRDATA[LEN-1:0]), .q(FetchBuffer));
if(LSU) begin
// delay HWDATA by 1 cycle per spec; assumes AHBW = XLEN
flop #(`XLEN) wdreg(HCLK, WriteData, HWDATA);
flop #(`XLEN/8) HWSTRBReg(HCLK, ByteMask, HWSTRB);
end else begin
assign HWDATA = '0;
assign HWSTRB = '0;
end
busfsm busfsm(.HCLK, .HRESETn, .Flush, .BusRW,
.BusCommitted, .Stall, .BusStall, .CaptureEn, .HREADY,
.HTRANS, .HWRITE);
endmodule