/////////////////////////////////////////// // fpuhazard.sv // // Written: me@KatherineParry.com 19 May 2021 // Modified: // // Purpose: Determine forwarding, stalls and flushes for the FPU // // A component of the Wally configurable RISC-V project. // // Copyright (C) 2021 Harvey Mudd College & Oklahoma State University // // MIT LICENSE // Permission is hereby granted, free of charge, to any person obtaining a copy of this // software and associated documentation files (the "Software"), to deal in the Software // without restriction, including without limitation the rights to use, copy, modify, merge, // publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons // to whom the Software is furnished to do so, subject to the following conditions: // // The above copyright notice and this permission notice shall be included in all copies or // substantial portions of the Software. // // THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, // INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR // PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS // BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, // TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE // OR OTHER DEALINGS IN THE SOFTWARE. //////////////////////////////////////////////////////////////////////////////////////////////// `include "wally-config.vh" module fhazard( input logic [4:0] Adr1E, Adr2E, Adr3E, // read data adresses input logic FRegWriteM, FRegWriteW, // is the fp register being written to input logic [4:0] RdM, RdW, // the adress being written to input logic [1:0] FResSelM, // the result being selected output logic FStallD, // stall the decode stage output logic [1:0] FForwardXE, FForwardYE, FForwardZE // select a forwarded value ); always_comb begin // set defaults FForwardXE = 2'b00; // choose FRD1E FForwardYE = 2'b00; // choose FRD2E FForwardZE = 2'b00; // choose FRD3E FStallD = 0; //*** this hazard unit is waiting for all three inputs, change so that if an input isnt used then don't wait // if the needed value is in the memory stage - input 1 if ((Adr1E == RdM) & FRegWriteM) // if the result will be FResM (can be taken from the memory stage) if(FResSelM == 2'b00) FForwardXE = 2'b10; // choose FResM else FStallD = 1; // otherwise stall // if the needed value is in the writeback stage else if ((Adr1E == RdW) & FRegWriteW) FForwardXE = 2'b01; // choose FPUResult64W // if the needed value is in the memory stage - input 2 if ((Adr2E == RdM) & FRegWriteM) // if the result will be FResM (can be taken from the memory stage) if(FResSelM == 2'b00) FForwardYE = 2'b10; // choose FResM else FStallD = 1; // otherwise stall // if the needed value is in the writeback stage else if ((Adr2E == RdW) & FRegWriteW) FForwardYE = 2'b01; // choose FPUResult64W // if the needed value is in the memory stage - input 3 if ((Adr3E == RdM) & FRegWriteM) // if the result will be FResM (can be taken from the memory stage) if(FResSelM == 2'b00) FForwardZE = 2'b10; // choose FResM else FStallD = 1; // otherwise stall // if the needed value is in the writeback stage else if ((Adr3E == RdW) & FRegWriteW) FForwardZE = 2'b01; // choose FPUResult64W end endmodule